Underfloor heating installation guides

Choose a flooring product approved for underfloor heating and follow its temperature, thermal-resistance and installation limits. The Ribbon is 1.8mm thick, but insulation, underlay, rigid preparation and the floor finish add to the complete build-up. These guides explain the different preparations, layers and installation checks for each floor type.

Updated 29 September 2026

Choose the guide for your exact floor finish below. Each covers the required floor layers, subfloor preparation, whole-mat layout and checks before the floor goes on top. The build-up differs between carpet, tile, wood, laminate and vinyl, so confirm the complete construction before buying or fitting. Arrange a qualified electrician for electrical design, protection, testing, connection and commissioning. The amount of preparation and fitting time depends on the room and its existing floor.

Download the full fitting guide

The fitting guide covers room planning, floor constructions, Ribbon fitting rules, controls and electrical checks, performance, warranty conditions and current products.

Download the fitting guide (PDF)

Free, no email needed. Use the guide alongside the supplied product instructions and your electrician’s installation plan.

Pick your floor type

More help

Tell us your floor and room in the heating selector. A straightforward room gets a product list you can add to your basket. Anything unusual goes to Russ with your answers attached.

Prefer to talk it through first? Call us on 01244 822 918. We are based in Flint, North Wales, and we are happy to help you plan the job. Tell us your room size and floor type and we will tell you exactly what you need.

See the heating and flooring samples

A closer look at the demonstration samples. Confirm the complete floor build-up, controls and installation requirements for your chosen products.

Heating ribbon connection with a black insulation sleeve and a separate metal connector.
Heating ribbon connection with a black insulation sleeve and a separate metal connector (demonstration sample).

Watch Russell explain

Check the fitting requirementsRead the full dos and don’ts and download the quick guide.

Fitting it right, Do’s & Don’ts

Quick rules for fitters and DIYers. Start with the right floor build-up, layout and electrical checks.

DO

  • Choose insulation for your floor construction. Therm-All suits appropriate floating floors; tiles and stone need a suitable rigid insulating or backer construction. Check the subfloor and moisture protection.
  • Plan useful floor coverage around the room’s heat loss and flooring. Around 70–80% is a planning aim; coverage alone does not prove primary heat or require an infrared panel.
  • Check the open front toe-kick of kitchen units separately. Approximately the front 300mm may be considered when it is open and suitable. Keep the deep solid-base recess clear.
  • Keep unconfirmed wet fixtures and appliances excluded. Baths, showers and kitchen units need a separate installation check; an air gap alone does not approve heating underneath.
  • Use a compatible floating engineered board and the correct underlayer. Our guidance covers compatible boards up to 22mm. Follow the board manufacturer’s instructions. Solid timber needs its own batten construction unless its manufacturer specifies otherwise.
  • Level the subfloor and check your flooring product is suitable before you start.
  • Follow the flooring manufacturer’s jointing and installation instructions.
  • Mount the thermostat in the right room, at the right height, each whole mat belongs to one control zone. Allow at most 20m² of fitted mats per thermostat, with at least two zones for a kitchen-diner; an electrician must check the controller load and wiring.
  • Involve a qualified electrician for electrical design, protection, final connection, testing and certification.

DON’T

  • Do not assume every floor is a dry installation. The Ribbon is 1.8mm thick, but some specified floor finishes need a levelling or approved overlay construction. Check every layer in the chosen assembly.
  • Check both carpet limits. Underlay must be no higher than 0.8 TOG, and carpet plus underlay no higher than 2.8 TOG. Use products approved for the selected heating system.
  • Use only the specified floor layers above the heating. Avoid unapproved insulating coverings, foam and furniture that trap heat. Follow the complete fitting instructions for the selected floor finish.
  • Confirm the solid-timber construction before fitting. Use battens unless the board manufacturer specifies otherwise, and check the complete build-up with us and the flooring manufacturer.
  • Don’t leave a gap round the edges of the room. The Ribbon needs no perimeter gap, run it right up to the walls. Your floating boards still get the expansion gap the flooring maker specifies, but that sits in the floor above, not in the heating.
  • Do not make the final electrical connection yourself. Arrange a qualified electrician for connection, testing and certification.

The printable quick guide covers the key fitting checks. Read it alongside the full guide and supplied manufacturer instructions.

Download the quick fitting guide (PDF)

Work out the heating for your room

Answer a few plain questions about your floor and room. A straightforward room gets a product list you can add to your basket in one go. Anything more involved goes to Russ with your answers attached.